Filters
Question type

Study Flashcards

Commissurotomy is a surgical separation of the flaps of the:


A) mitral valve
B) left ventricle
C) pulmonary valve
D) right atrium

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

Which instrument is used to make a small opening into the ascending aorta after the Satinsky partial occlusion clamp is placed?


A) aortic punch
B) Potts-Smith scissors
C) #11 blade
D) 5 mm trocar

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

Which of the following is a commonly used method of preserving the heart by reducing its metabolic needs?


A) hypothermia
B) lung deflation
C) left ventricular venting
D) warming with heat exchanger

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

Which suturing technique maintains the aortic and venous cannulae?


A) figure of eight
B) purse-string
C) horizontal mattress
D) vertical mattress

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

How many pulmonary veins are there?


A) one
B) two
C) three
D) four

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

Which device is used for patients awaiting heart transplant that allows them to be ambulatory and has both internal and external components to the system?


A) ventricular assist device
B) left ventricular vent
C) cardiac pacemaker
D) vena cava filter

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

What is the medical term for coughing up blood?


A) asthma
B) bronchitis
C) hemoptysis
D) pneumonitis

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

Medtronic OCTOPUS® and Guidant Ultima OPCAB® are what type of devices for coronary artery bypass done off-pump?


A) retractors
B) stabilizers
C) cannulae
D) grafts

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

What is the name of the device used for patients who are unable to be weaned off of cardiopulmonary bypass?


A) intra-aortic balloon pump
B) left ventricular vent
C) cardiac pacemaker
D) vena cava filter

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Which structure within the respiratory tract is the proximal and superior?


A) bronchus
B) diaphragm
C) larynx
D) trachea

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

What is the name of the device that is attached to suction for collection of mucous or bronchial washing specimens?


A) aerobic culture tube
B) insufflation tubing
C) myringotomy tube
D) Lukens tube

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

Which nerve could be damaged during lung decortication resulting in paralysis or partial paralysis of the diaphragm?


A) accessory
B) hypoglossal
C) phrenic
D) vagus

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

What is the general term for incurable diseases of the heart for which the only treatment would be heart transplantation?


A) atherosclerosis
B) arrhythmias
C) cardioplegia
D) cardiomyopathies

E) C) and D)
F) B) and C)

Correct Answer

verifed

verified

Which of the following is the main underlying pathogenic cause of coronary atherosclerosis and clinical manifestations?


A) age
B) diet
C) ischemia
D) hypertension

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Which instrument is a rib shear?


A) Alexander
B) Bethune
C) Davidson
D) Satinsky

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

The ventricles of the heart have thicker myocardium than the atria.

A) True
B) False

Correct Answer

verifed

verified

Which diagnostic study is MOST useful for verification of thoracic aortic dissection?


A) AP chest x-ray
B) CT scan
C) MRI scan
D) stress test

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

What is the term for a collapsed lung?


A) atelectasis
B) decortication
C) emphysema
D) pneumonitis

E) A) and C)
F) All of the above

Correct Answer

verifed

verified

Which chamber of the heart is responsible for pumping blood into the pulmonary artery?


A) left atrium
B) right atrium
C) left ventricle
D) right ventricle

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The drainage and collection device attached to chest tubes relies on a water seal to reestablish negative pressure in the pleural cavity.

A) True
B) False

Correct Answer

verifed

verified

Showing 21 - 40 of 81

Related Exams

Show Answer